ZW20-12F (M) Outdoor High Voltage Intelligent (Permanent Magnet) Vacuum Circuit Breaker


The ZW20-12F (M) outdoor high-voltage intelligent (permanent magnet) vacuum circuit breaker is an outdoor high-voltage switchgear with a rated voltage of 12kV and three-phase AC 50/60Hz. Mainly used for breaking and closing load current, overload current, and short-circuit current of power systems


Product Overview

The ZW20-12F (M) outdoor high-voltage intelligent (permanent magnet) vacuum circuit breaker is an outdoor high-voltage switchgear with a rated voltage of 12kV and three-phase AC 50/60Hz. Mainly used for breaking and closing load current, overload current, and short-circuit current of power systems

Suitable for protection and control of substations, industrial and mining enterprises, as well as urban and rural distribution networks, especially suitable for frequently operated places and urban automation distribution networks. This product is paired with a controller, which can meet the requirements of distribution automation systems and reliably and effectively complete traditional recloser functions. It adopts a mature box sealing structure and has good sealing performance, making it not affected by the external environment. It is a maintenance free product. Its spring operating mechanism or permanent magnet operating mechanism has high reliability in operation, making it a good choice for pole mounted circuit breakers.

 

Product Features

 

Miniaturized design;

The box has an inverted buckle structure, fully sealed, simple sealing effect, and high anti fouling level;

The transmission method is novel, simple and reliable;

The main components are sealed inside the box, achieving true maintenance free;

Voltage transformer and disconnector can be installed externally.

 

Conditions of Use

Working environment temperature: not exceeding 40 ° C; The daily average temperature does not exceed 35 ℃; The minimum ambient air temperature is -25 ℃;

Relative humidity of the air: The daily average value shall not exceed 95%, and the monthly average value shall not exceed 90%; The daily average value of Vapour pressure of water is not more than 2.2kPa, and the average value is not more than 1.8kPa;

Altitude: not exceeding 2000m;

The surrounding area is not significantly polluted by dust, smoke, corrosive and/or combustible gases, vapors, or salt mist. Vibration or ground motion from outside the switchgear and control equipment can be ignored;

The amplitude of induced electromagnetic interference in the secondary system shall not exceed 1.6kV.